Approvals & Standards

  • Complies to Automotive IATF 16949:2016 Quality System
  • IEC 60 269-4
  • ISO 8820-8
  • JAS0 D622

Key features & benefits

EVpack-fuse line-up belongs to Mersen’s DC Over-Current protection (O.C.P.) portfolio specifically developed to address on-board electric and hybrid vehicles applications.
EVpack-fuse provides the ultimate protection by offering reliable clearing of DC fault currents in challenging environments and complies with the high-quality requirements of the automotive industry.
The MEV55C has specifically engineered and tested to provide best-in-class protection performance for auxiliary circuits: Up to 550VDC, Current rating (In)= 5 to 50A, Interrupting Rating (IR) = 20kA,L/R ≤1ms, Minimum Breaking Capacity (MBC) as low as 2xIn for a perfect matching with cable protection.
The MEV50A has been specifically engineered and tested to provide best-in-class protection performance for main battery and on-board charging protection: Up to 500VDC, Current rating (In)= 60 to 800A, Interrupting Rating (IR) = 30kA, L/R ≤ 2.5ms, Minimum Breaking Capacity (MBC) as low as 2xIn or a perfect matching with DC contactor.

More specifications

Applications

  • EV/HEV
  • Battery pack protection
  • Battery Disconnect Unit (BDU)
  • Battery Management Systm (BMS)
  • Battery Junction Box for auxiliaries
  • On-Board Charging

Product Specifications

Item Number

MEV50A600-45G  

Catalog number

MEV50A600-45G  

Description

EVpack Fuse 500VDC UL 500VDC IEC 600A Size 45G Max. Rated Breaking Capacity DC: 30 kA @ 500 V, L/R ≤ 2.5 ms Bolted  

EAN/UPC code

6972238870394  

Rated voltage DC UL

500   V

Rated voltage DC IEC

500   V

Rated current

600   A

ROHS Compliant

Yes  

AC or DC

DC  

Speed/Characteristic

aR  

Fuse size

45G  

Mounting

Bolted  

Melting I2t

73750   A²s

Max. Rated Breaking Capacity DC

30 kA @ 500 V, L/R ≤ 2.5ms  

Max. Time to clear MBC

3.5   s

DC Min. Breaking Capacity (MBC)

2000 A @ 500 VDC, ≤ 2.5 ms  

DC Total clearing I2t

565000 A²s  

Power Dissipation at Intermediate Current Value

18.2 W @ 0.5 In  

Contact materials

Tin-Plated Copper  

Connection/Terminal Type

Bolted  

Body/Insulating Material

GMG  

Product Weight

0.24   kg

Product Diameter

45   mm

Product Length

103   mm

Sell Pack Quantity

4   EA

Sell Pack Weight

0.96   kg

Sell Pack Width

288   mm

Sell Pack Length

176   mm

Sell Pack Height

107   mm